IDEXX Tecta® System

21st June 2024

     

Font size: - +

Complete, self-contained water testing system IDEXX Tecta® provides rapid evidence of bacterial contamination by coliforms, E. coli, faecal coliforms, or Enterococci, outside of a traditional laboratory setting.

The system features the option to simultaneously run up to four or 16 analyses, providing fully automated incubation and test interpretation. Results are automatically sent by email, eliminating any testing delays caused by working around staff availability. 

Water samples are added to the appropriate ‘Tectalert’ cartridge, which is then loaded into the Tecta instrument. The result is continuously monitored throughout the testing process and an email alert is generated when a positive result is detected, obviating the need for testing to be restricted by working around shift patterns. Positive results can be available in as little as two hours, subject to the level of contamination, with negative results confirmed in 18 or 24 hours, depending on test type.

The instrument has a very wide detection range from <1 to 108 colony forming units (CFUs) per 100 ml.  Samples can be run undiluted and can originate from a variety of water matrices, including bio-solids. The detection method removes possible human discrepancies of result interpretation and is unaffected by the colour and turbidity of the sample.

The Tecta system allows sampling and testing to be carried out in a wide range of scenarios and locations where traditional testing methods could prove challenging, as the simplicity and flexibility of Tecta enables the “laboratory” to be taken to samples, rather than transporting samples for up to several hours in the case of remote areas. Its novel, fully automated method eliminates the need for staff to be present within the ‘read’ window for results, allowing samples to be tested at any time of day, and monitoring to be fully dynamic to respond to circumstances. Its wide detection range means samples that would usually require dilution, such as those with complex particulate loading or colour, can be run without any processing, accelerating the time to results.

®Registered trademark of IDEXX Laboratories, Inc. or its affiliates in the United States and/or other countries.

Edited by Creamer Media Reporter

Comments

Showroom

Essentra Components
Essentra Components

We are responsible manufacturers of essential components. Manufacturing 80 million parts a week, we have over 1 billion parts in stock.

VISIT SHOWROOM 
Weir
Weir

Weir is a global leader in mining technology. We recognise that our planet’s future depends on the transition to renewable energy, and that...

VISIT SHOWROOM 

Latest Multimedia

sponsored by

Magazine round up | 04 April 2025
Magazine round up | 04 April 2025
4th April 2025

Option 1 (equivalent of R125 a month):

Receive a weekly copy of Creamer Media's Engineering News & Mining Weekly magazine
(print copy for those in South Africa and e-magazine for those outside of South Africa)
Receive daily email newsletters
Access to full search results
Access archive of magazine back copies
Access to Projects in Progress
Access to ONE Research Report of your choice in PDF format

Option 2 (equivalent of R375 a month):

All benefits from Option 1
PLUS
Access to Creamer Media's Research Channel Africa for ALL Research Reports, in PDF format, on various industrial and mining sectors including Electricity; Water; Energy Transition; Hydrogen; Roads, Rail and Ports; Coal; Gold; Platinum; Battery Metals; etc.

Already a subscriber?

Forgotten your password?

MAGAZINE & ONLINE

SUBSCRIBE

RESEARCH CHANNEL AFRICA

SUBSCRIBE

CORPORATE PACKAGES

CLICK FOR A QUOTATION







sq:0.119 1.538s - 151pq - 2rq
Subscribe Now